Field / type | MDR 2102FS | MDR 2105FS | MDR 2108FS |
Supply voltage | 1 × 100...230 VAC [± 10 %], | 1 × 100...230 VAC [± 10 %], 50...60 Hz | 1 × 100...230 VAC [± 10 %], |
Alternative DC-input | 60...380 VDC | 60...380 VDC | 60...380 VDC |
Control voltage | 24 VDC | 24 VDC | 24 VDC |
Intermediate circuit voltage | 360...380 VDC 1) / 310...320 VDC 2), 3) | 360...380 VDC 1) / 310...320 VDC 2), 3) | 360...380 VDC 1) / 310...320 VDC 2), 3) |
Pulse frequency | Variable pulse frequencies up to 20 kHz, Data for operation on | Variable pulse frequencies up to 20 kHz , Data for operation on | Variable pulse frequencies up to 20 kHz, Data for operation on |
Nominal output power | 0,5 kVA | 0,5 kVA | 0,5 kVA |
Max. output power for 5 s | 1,0 kVA | 1,0 kVA | 1,0 kVA |
Nominal output current | 2,5 Aeff | 2,5 Aeff | 2,5 Aeff |
Max. output current für 5 s | 5 Aeff | 5 Aeff | 5 Aeff |
Max. output current for 0,5 s | 10 Aeff | 10 Aeff | 10 Aeff |
Current derating from | 12 kHz | 12 kHz | 12 kHz |
Internal brake resistance | 60 Ohm | 60 Ohm | 60 Ohm |
Continuous/Pulse power | 10 W/2,8 kW | 10 W/2,8 kW | 10 W/2,8 kW |
External brake resistance | 50 Ohm | 50 Ohm | 50 Ohm |
Holding brake | 24 VDC, max. 1 A | 24 VDC, max. 1 A | 24 VDC, max. 1 A |
Certification | UL certified | UL certified | UL certified |
Dimensions basic device h x w x d5) | 200 × 54 × 200 mm | 200 × 54 × 200 mm | 200 × 54 × 200 mm |
Weight | 2,0 kg | 2,0 kg | 2,0 kg |
Field / type | MDR 2302FS | MDR 2302FS | MDR 2310FS |
Supply voltage | 3 × 230...480 VAC [± 10 %], 50...60 Hz | 3 × 230...480 VAC [± 10 %], 50...60 Hz | 3 × 230...480 VAC [± 10 %], 50...60 Hz |
Alternative DC-input | 60...700 VDC | 60...700 VDC | 60...700 VDC |
Control voltage | 24 VDC | 24 VDC | 24 VDC |
Intermediate circuit voltage | 560 VDC | 560 VDC | 560 VDC |
Pulse frequency | Variable pulse frequencies to 16 kHz, Data for operation on 3 × 400 VAC, 50 Hz | Variable pulse frequencies to 16 kHz, Data for operation on 3 × 400 VAC, 50 Hz | Variable pulse frequencies to 16 kHz, Data for operation on 3 × 400 VAC, 50 Hz |
Nominal output power | 1,5 kVA | 1,5 kVA | 1,5 kVA |
Max. output power for 5 s | 3,0 kVA | 3,0 kVA | 3,0 kVA |
Nominal output current | 2,5 Aeff | 2,5 Aeff | 2,5 Aeff |
Max. output current for 5 s | 7,5 Aeff / 5 Aeff 3) | 7,5 Aeff / 5 Aeff 3) | 7,5 Aeff / 5 Aeff 3) |
Max. output current 0,5 s | 10 Aeff | 10 Aeff | 10 Aeff |
Current derating from | 12,5 kHz | 12,5 kHz | 12,5 kHz |
Internal brake resistance | 68 Ohm | 68 Ohm | 68 Ohm |
Continuous/Pulse power | 110 W/8,5 kW | 110 W/8,5 kW | 110 W/8,5 kW |
External brake resistance | 40 Ohm | 40 Ohm | 40 Ohm |
Holding brake | 24 VDC, max. 2 A | 24 VDC, max. 2 A | 24 VDC, max. 2 A |
Certification | UL certified | UL certified | UL certified |
Dimensions basic device h x w x d5) | 250 × 69 × 240 mm | 250 × 69 × 240 mm | 250 × 69 × 240 mm |
Weight | 3,7 kg | 3,7 kg | 3,7 kg |
1) MDR 2102 FS / MDR 2105 FS with active PFC
2) MDR 2102 FS / MDR 2105 FS without active PFC
3) MDR 2000 SE
4) Shorter times for lower electric rotary frequency (fel)
5) Without mounting plate and fan