The machine is suitable for a simultaneous test of up to:
4 ribbon cables, width up to 140 mm or
8 round cables, diameter up to 20 mm or
8 fibre glass cables, diameter up to 20 mm.
The maximum diameter of each test pulley is 250 mm.
Test process unit with a maximum traveling distance of up to 1600 mm.
The front plate of the control console contains 4 control sections, each consisting of the current display, the control button, the function display and a protection system. At 400 V AC, a current of 30 mA to 230 mA can be adjusted for each one of the 4 test sample. This allows to test 4 different types of cables simultaneously.
The following failure situations are communicated to the SPS in the process unit:
1. cable interruption
2. short-circuit between 2 cables
3. short-circuit to ground